Count | Lab Number and Name |
Section 1 | |
1 | Lab 2.1 HVACR Jobs |
2 | Lab 2.2 HVACR Organizations |
3 | Lab 3.1 Material Safety Data Sheets |
4 | Lab 3.2 HVACR PPE |
5 | Lab 3.3 Locate Safety Equipment |
6 | Lab 3.4 Ladder Safety |
7 | Lab 4.1 Using Hand Tools |
8 | Lab 5.1 Fastener Identification |
Section 2 | |
9 | Lab 7.1 Balloon — Gas Volume vs. Temperature |
10 | Lab 7.2 Weighing Solids, Liquids, and Gases |
11 | Lab 7.3 Measuring Density, Specific Volume, and Specific Gravity |
12 | Lab 8.1 Energy Conversion |
13 | Lab 9.1 Measuring Temperature |
14 | Lab 10.1 Boiling Point vs. Pressure |
15 | Lab 10.2 Pressure Temperature Relationship of Saturated Mixtures |
16 | Lab 10.3 Sensible and Latent Heat |
17 | Lab 10.4 Determining Refrigerant Condition |
18 | Lab 10.5 Measuring Heat Pump System Capacity |
19 | Lab 10.6 Sensible and Latent Heat |
20 | Lab 10.7 Saturated Pressure-Temperature Relationships |
21 | Lab 10.8 Saturated, Superheated, or Subcooled |
22 | Lab 11.1 Quantity Pressure Relationship of Ideal Gases |
23 | Lab 11.2 Gas Temperature and Volume at Constant Pressure |
24 | Lab 11.3 Gas Pressure Temperature Relationship at a Constant Volume |
25 | Lab 11.4 Gas Pressure Temperature Volume Relationship |
26 | Lab 11.5 Air Compression & Expansion |
27 | Lab 11.6 Ideal Gas Laws |
Section 3 | |
28 | Lab 14.1 Identifying Refrigeration System Components |
29 | Lab 14.2 Identifying Refrigeration System Components |
30 | Lab 14.3 Trainer Refrigeration System Characteristic |
31 | Lab 14.4 Packaged Unit Refrigeration System Characteristics |
32 | Lab 14.5 Split System Refrigeration Characteristics |
33 | Lab 14.6 Bench Unit Refrigeration System Characteristics |
34 | Lab 14.7 Water Cooled System Characteristics |
35 | Lab 14.8 Refrigerant Identification |
36 | Lab 14.9 Refrigerant Oil Identification |
37 | Lab 15.1 Identifying Compressors |
38 | Lab 15.2 Semi-Hermetic Compressor Inspection |
39 | Lab 15.3 Hermetic Compressor Inspection |
40 | Lab 15.4 Rotary Compressor Inspection |
41 | Lab 15.5 Scroll Compressor Inspection |
42 | Lab 15.6 Determining Compression Ratio |
43 | Lab 15.7 Compressor Autopsy |
44 | Lab 16.1 Air Cooled Condenser Performance |
45 | Lab 16.2 Water Cooled Condenser Performance |
Lab 16.3 Waterflow Effect on System Performance (see Lab 92.1) | |
Lab 16.4 Effect of Airflow on System Performance (see Lab 92.2) | |
46 | Lab 17.1 Internally Equalized Thermostatic Expansion Valves |
47 | Lab 17.2 Externally Equalized Thermostatic Expansion Valves |
48 | Lab 17.3 Setting a Thermostatic Expansion Valve |
49 | Lab 17.4 Types of Metering Devices |
50 | Lab 17.5 Adjusting Automatic Expansion Valves |
51 | Lab 17.6 Disassembling TEVs |
52 | Lab 17.7 TEV Installation |
53 | Lab 17.8 Adjusting Valve Superheat |
54 | Lab 17.9 Capillary Tube Assembly & Operation |
55 | Lab 18.1 Installing Condensate Drain |
Lab 18.2 Waterflow Effect on System Performance (see Lab 92.1) | |
Lab 18.3 Effect Of Airflow on System Performance (see Lab 92.2) | |
56 | Lab 19.1 Identifying Refrigerants and Refrigerant Characteristics |
57 | Lab 19.2 Identifying Refrigerant Lubricant Characteristics |
58 | Lab 20.1 Solenoid Valves |
59 | Lab 20.2 Setting an Evaporator Pressure Regulator |
60 | Lab 20.3 Identifying Accessories |
61 | Lab 20.4 Installing Accessories |
62 | Lab 21.1 Describe the Refrigeration System Characteristics Using a Refrigeration Trainer |
Section 4 | |
63 | Lab 22.1 Disposable Refrigerant Cylinders |
64 | Lab 22.2 Refillable Refrigerant Recovery Cylinders |
65 | Lab 22.3 Refrigerant Cylinders |
66 | Lab 23.1 Refrigerant Gauge Manifolds |
67 | Lab 23.2 Refrigeration Equipment Familiarization |
68 | Lab 24.1 Identifying Fittings |
69 | Lab 24.2 Flaring |
70 | Lab 24.3 Swaging |
71 | Lab 25.1 Soldering Copper Pipe |
72 | Lab 25.2 Brazing |
73 | Lab 25.3 Lighting The Torch |
74 | Lab 25.4 Soldering Copper Tubing |
75 | Lab 25.5 Oxy-Acetylene Torch Safety |
76 | Lab 25.6 Brazing |
77 | Lab 27.1 Schrader, Piercing, and Service Valves |
78 | Lab 27.2 Service Valve Inspection |
79 | Lab 27.3 Installing Gauges On Schrader Valves |
80 | Lab 27.4 Installing Manifold Gauges On Manual Stem Service Valves |
81 | Lab 28.1 Recovery Unit |
82 | Lab 28.2 Refrigerant Vapor Recovery Self Contained Active |
83 | Lab 28.3 Liquid Recovery Self-Contained Active |
84 | Lab 28.4 Liquid Recovery System Dependent Passive |
Lab 28.5 Refrigeration Equipment Familiarization (see Lab 23.2) | |
Lab 28.6 Refrigerant Cylinders (see Lab 22.3) | |
85 | Lab 28.7 Packaged Unit Recovery |
86 | Lab 28.8 Split System Recovery |
87 | Lab 28.9 System Pumpdown |
88 | Lab 29.1 Electronic Leak Detector |
89 | Lab 29.2 Halide Torch Leak Detector |
90 | Lab 29.3 Nitrogen Pressure Test |
91 | Lab 29.4 Detecting Leaks Using Nitrogen And Soap Bubbles |
92 | Lab 29.5 Detecting Leaks Using Ultrasonic Leak Detector |
93 | Lab 29.6 Detecting Leaks Using A Halide Torch |
94 | Lab 29.7 Detecting Leaks Using An Electronic Sniffer |
95 | Lab 29.8 Detecting Leaks Using A Fluorescent Dye And A Black Light |
96 | Lab 30.1 Vacuum Pump |
97 | Lab 30.2 Deep Method of Evacuation |
98 | Lab 30.3 Triple Evacuation |
99 | Lab 30.4 Vacuum Pressure Drop Test |
Lab 30.5 Refrigeration Equipment Familiarization (see Lab 23.2) | |
100 | Lab 31.1 Charging Cylinder |
101 | Lab 31.2 Vapor Charging with Charging Cylinder |
102 | Lab 31.3 Vapor Charging with Digital Scale |
103 | Lab 31.4 Liquid Charging with Compressor Off |
104 | Lab 31.5 Liquid Charging with Compressor Running |
105 | Lab 31.6 Liquid Charging with Blends Zeotropes |
Lab 31.7 Refrigeration Equipment Familiarization (see Lab 23.2) | |
106 | Lab 31.8 Charging By Weight Packaged Unit |
107 | Lab 31.9 Charging By Weight Split System |
108 | Lab 31.10 Pressure-Temperature Method |
109 | Lab 31.11 Vapor Charge — Pressure/Temperature |
110 | Lab 31.12 Superheat Charging |
111 | Lab 31.13 Vapor Charge — Superheat |
112 | Lab 31.14 Subcooling Method |
113 | Lab 31.15 Manufacturer’s Charging Chart |
114 | Lab 31.16 Checking Charge On Water Cooled System |
Section 5 | |
115 | Lab 32.1 Using Non-Contact Voltage Detectors |
116 | Lab 32.2 Electrical Safety Procedures |
117 | Lab 32.3 Changing Fuses |
118 | Lab 33.1 Series and Parallel Circuits |
119 | Lab 33.2 Apply Ohms Law to Series Circuit Voltage Changes |
120 | Lab 33.3 Ohms Law & Parallel Circuit Voltage Changes |
121 | Lab 34.1 Alternating Current Principles |
122 | Lab 34.2 Alternating Current Demonstration |
123 | Lab 34.3 Identification of Relay & Contactor Parts |
124 | Lab 35.1 Electrical Multimeters |
125 | Lab 35.2 Using Volt Meters |
126 | Lab 35.3 Using Amp Meters |
127 | Lab 35.4 Using Ohm Meters |
128 | Lab 35.5 Checking Resistors |
129 | Lab 36.1 Setting the High Pressure Cutout |
130 | Lab 36.2 Setting the Low Pressure Cutout |
131 | Lab 36.3 Setting a Box Thermostat Control |
132 | Lab 36.4 Testing a Capacitor |
133 | Lab 36.5 Identify Components on Air Conditioning Diagram |
134 | Lab 36.6 Identify Components on Heat Pump Diagram |
135 | Lab 36.7 Identifying Start and Run Capacitors |
136 | Lab 36.8 Checking Start and Run Capacitors Using Multi-meter |
137 | Lab 36.9 Identifying Overloads |
138 | Lab 36.10 Troubleshooting Thermal Overloads |
139 | Lab 36.11 Pilot Duty Overload Operation |
140 | Lab 36.12 Magnetic Starter Familiarization |
141 | Lab 36.13 Wiring Magnetic Starter with a Toggle Switch |
142 | Lab 36.14 Wiring Magnetic Starter with a Start-Stop Switch |
143 | Lab 36.15 Electrical Component Identification |
144 | Lab 36.16 Identification of Relay & Contactor Parts |
145 | Lab 36.17 Examining Low Voltage Thermostats |
146 | Lab 36.18 Examining Line Voltage Thermostats |
147 | Lab 36.19 Identify Pressure Switches |
148 | Lab 36.20 Testing Transformers |
149 | Lab 36.21 Checking Low Voltage Thermostats |
150 | Lab 36.22 Checking Relays and Contactors |
151 | Lab 36.23 Setting Low Pressure Cutout |
152 | Lab 36.24 Setting High Pressure Cutouts |
153 | Lab 37.1 Testing Windings on a Single Phase Motor |
154 | Lab 37.2 Motor Insulation Testing |
155 | Lab 37.3 Types of Electric Motors |
156 | Lab 37.4 Examine Shaded Pole Motor |
157 | Lab 37.5 Inspecting Open Split Phase Motor |
158 | Lab 37.6 Inspecting Open Capacitor Start Motor |
159 | Lab 37.7 Inspecting Permanent Split Capacitor (PSC) Motor |
160 | Lab 37.8 Wire and Operate Shaded Pole Motors |
161 | Lab 37.9 Troubleshooting Shaded Pole Motors |
162 | Lab 37.10 Wire and Operate Open Split Phase and Capacitor Start Motors |
163 | Lab 37.11 Troubleshooting Open Split Phase & Capacitor Start Motors |
164 | Lab 37.12 Wire and Operate Open PSC Motors |
165 | Lab 37.13 Troubleshooting Open PSC Motors |
166 | Lab 37.14 Ohming Three Phase Motors |
167 | Lab 37.15 Wire and Operate Three Phase Motors |
168 | Lab 37.16 Examine ECM Motor |
169 | Lab 37.17 Operate ECM Motor |
170 | Lab 37.18 Check ECM Motor Using TECMATE |
171 | Lab 37.19 Set Blower CFM On ECM Blower Board |
172 | Lab 37.20 Troubleshooting CSR Motors |
173 | Lab 37.21 Troubleshooting Motors |
174 | Lab 38.1 Wiring Diagrams |
175 | Lab 38.2 Wiring Transformers |
176 | Lab 38.3 Wiring Contactors |
177 | Lab 38.4 Wiring Relays |
178 | Lab 38.5 Identify Electric Component Symbols |
179 | Lab 38.6 Identify Components on Air Conditioning Diagram |
180 | Lab 38.7 Identify Components on Heat Pump Diagram |
181 | Lab 39.1 Draw Window Unit Diagram |
182 | Lab 39.2 Wire Window Unit Diagram |
183 | Lab 39.3 Draw Packaged AC Unit Diagram |
184 | Lab 39.4 Wire Packaged AC Diagram |
185 | Lab 39.5 Draw 2 Stage Heat 2 Stage Cool Diagram |
186 | Lab 39.6 Wire 2 Stage Heat 2 Stage Cool Diagram |
187 | Lab 39.7 Wire a Heating and Cooling Thermostat |
188 | Lab 39.8 Wire a Packaged Heat Pump Thermostat |
189 | Lab 39.9 Design and Operate a Simple 120 Volt Relay Circuit |
190 | Lab 39.10 Design and Operate a Simple 24 Volt Relay Circuit |
191 | Lab 39.11 Design and Operate a Simple 24 Volt Contactor Circuit |
192 | Lab 39.12 Wiring a Relay Control System |
193 | Lab 39.13 Wiring Anti-Short Cycle Time Delays |
194 | Lab 39.14 Wiring Air Conditioning Control System |
195 | Lab 39.15 Wiring Commercial Packaged Unit |
196 | Lab 39.16 Wiring Two Stage Air Conditioning System |
Section 6 | |
197 | Lab 41.1 Using Sling Psychrometer |
198 | Lab 41.2 Using Electronic Hygrometer (Digital Psychrometer) |
Lab 41.3 Using Magnehelic Gauge (see Lab 73.3) | |
199 | Lab 42.1 Changing Panel Filters |
200 | Lab 42.2 Servicing Media Filters |
201 | Lab 42.3 Electronic Air Cleaners |
Lab 45.1 Wiring A Split System (see Lab 89.3) | |
202 | Lab 46.1 Duct Components |
203 | Lab 47.1 Basic Refrigeration System Startup |
Section 7 | |
204 | Lab 48.1 Principles of Combustion |
205 | Lab 48.2 Gas Safety Inspection |
206 | Lab 48.3 Servicing Gas Burners |
207 | Lab 49.1 Gas Furnace Characteristics |
208 | Lab 49.2 Natural Draft Furnace Components |
209 | Lab 49.3 Natural Draft Furnace Sequence of Operation |
210 | Lab 49.4 Induced Draft Furnace Components |
211 | Lab 50.1 Installing a Replacement Thermostat |
212 | Lab 50.2 Program Thermostat |
213 | Lab 50.3 Pilot Turndown Test — Thermocouple Type |
214 | Lab 50.4 Pilot Turndown Test — Flame Rob Type |
215 | Lab 50.5 Pilot Turndown Test — Flame Igniter Type |
216 | Lab 50.6 Separate Pilot Gas Pressure Regulator |
217 | Lab 50.7 Check/Test/Replace Hot Surface Igniter |
218 | Lab 50.8 Natural Draft Furnace Electrical Components |
219 | Lab 50.9 Induced Draft Electrical Components |
220 | Lab 50.10 Induced Draft Furnace Sequence of Operation |
221 | Lab 50.11 Wire a Natural Draft Furnace |
222 | Lab 50.12 Wire an Induced Draft Gas Furnace |
223 | Lab 50.13 Gas Valve Inspection |
224 | Lab 50.14 Adjusting Gas Regulators |
225 | Lab 50.15 Testing Standing Pilot Safety Devices |
226 | Lab 50.16 Checking Intermittent Pilot Ignition Systems |
227 | Lab 50.17 Direct Spark Ignition Controls |
228 | Lab 50.18 Troubleshooting DSI Control Systems |
229 | Lab 51.1 Gas Furnace Startup |
230 | Lab 51.2 Measure Gas Usage |
231 | Lab 51.3 Gas Furnace Combustion Testing |
232 | Lab 51.4 Measure Gas Furnace Thermal Efficiency |
233 | Lab 51.5 Checking Gas Pressure |
234 | Lab 51.6 Sizing Gas Lines |
235 | Lab 51.7 Installing Gas Piping |
236 | Lab 51.8 Inspecting Gas Regulators |
237 | Lab 51.9 Measuring Draft |
238 | Lab 51.10 Measuring Temperature Rise |
239 | Lab 52.1 Gas Furnace Preventative Maintenance (PM) |
240 | Lab 52.2 Hot Surface Ignition Operation |
241 | Lab 52.3 Troubleshooting Hot Surface Ignition Systems |
242 | Lab 52.4 Vent Problems |
243 | Lab 52.5 Inspecting Heat Exchangers |
244 | Lab 52.6 Gas Combustion Efficiency |
245 | Lab 52.7 Troubleshooting Gas Furnace, Scenario 1 |
246 | Lab 52.8 Troubleshooting Gas Furnace, Scenario 2 |
247 | Lab 52.9 Troubleshooting Gas Furnace, Scenario 3 |
248 | Lab 52.10 Troubleshooting Gas Furnace, Scenario 4 |
249 | Lab 52.11 Troubleshooting Gas Furnace, Scenario 5 |
250 | Lab 52.12 Troubleshooting Gas Furnace, Scenario 6 |
251 | Lab 54.1 Oil Burner Tune Up |
252 | Lab 54.2 Final Oil Burner Adjustment |
253 | Lab 54.3 Oil Furnace Preventative Maintenance |
254 | Lab 54.4 Install a Replacement Fuel Oil Pump |
255 | Lab 55.1 Oil Fired Furnace Startup |
256 | Lab 55.2 Oil Furnace Storage Tank Maintenance |
257 | Lab 55.3 Oil Furnace Two Pipe Conversion |
258 | Lab 55.4 Install a Replacement Fuel Oil Burner |
259 | Lab 55.5 Check/Test a Cad Cell Oil Burner Primary Control |
Section 8 | |
260 | Lab 59.1 Wiring Sequencers |
261 | Lab 60.1 Electric Furnace Startup |
262 | Lab 60.2 Calculate Airflow by Temperature Rise |
263 | Lab 62.1 Types of Heat Pumps |
264 | Lab 62.2 Window Unit Heat Pump Refrigeration Cycle |
265 | Lab 62.3 Packaged Unit Heat Pump Refrigeration Cycle |
266 | Lab 62.4 Split System Heat Pump Refrigeration Cycle |
267 | Lab 62.5 Reversing Valve Fundamentals |
268 | Lab 62.6 Reversing Valve Operation |
269 | Lab 62.7 Heat Pump Electrical Components |
270 | Lab 63.1 Identifying Defrost Controls |
271 | Lab 63.2 Wiring Dual Fuel Heat Pump |
272 | Lab 63.3 Electric Strip Heat Operation |
273 | Lab 65.1 Wiring Packaged Heat Pump |
274 | Lab 65.2 Install Split System Heat Pump Refrigeration Piping |
Lab 65.3 Wire Disconnect Switch And Power Supply (see Lab 89.1) | |
275 | Lab 65.4 Wire Thermostat And Control Wiring |
276 | Lab 65.5 Evacuate And Charge A Split System Heat Pump |
277 | Lab 65.6 Split System Start and Check |
278 | Lab 65.7 Determining Balance Point |
279 | Lab 66.1 Packaged Heat Pump Charging — Cooling Cycle |
280 | Lab 66.2 Heat Pump Charging — Cooling Cycle Superheat |
281 | Lab 66.3 Heat Pump Charging — Cooling Cycle Subcooling |
Heating Cycle Charging Article | |
282 | Lab 66.4 Split System Heat Pump Charging — Cooling Cycle: Cold Ambient Temperature |
283 | Lab 66.5 Packaged Heat Pump Charging — Heating Cycle |
284 | Lab 66.6 Heat Pump Charging — Heating Cycle: Discharge Line Temperature |
285 | Lab 66.7 Heat Pump Charging — Heating Cycle: Temperature Rise |
286 | Lab 66.8 Checking Defrost Controls |
287 | Lab 66.9 Troubleshooting Heat Pumps, Scenario 1 |
288 | Lab 66.10 Troubleshooting Heat Pumps, Scenario 2 |
289 | Lab 66.11 Troubleshooting Heat Pumps, Scenario 3 |
Section 9 | |
290 | Lab 70.1 Manual J8 Block Load |
291 | Lab 70.2 Manual J8 Room by Room Load |
292 | Lab 72.1 Wiring Zone Control System |
293 | Lab 73.1 Rotating Vane Anemometer |
294 | Lab 73.2 Flow Hood |
295 | Lab 73.3 Using Magnehelic Gauge |
Lab 73.4 Using Sling Psychrometer (see Lab 41.1) | |
Lab 73.5 Using Electronic Hygrometer (Digital Psychrometer) (see Lab 41.2) | |
Section 10 | |
296 | Lab 75.1 Belt Drives |
297 | Lab 75.2 Direct Drive Motor Applications |
298 | Lab 75.3 AC Induction Motor Blower Properties |
299 | Lab 75.4 ECM Blower Properties |
Lab 76.1 Wiring a Packaged Unit (see Lab 89.2) | |
Lab 76.2 Wiring a Split System (see Lab 89.3) | |
300 | Lab 80.1 Water Circulating Pump Complete Service |
Section 11 | |
301 | Lab 88.1 Testing Start Relays |
302 | Lab 88.2 Ohming Single Phase Hermetic Compressor Motors |
303 | Lab 88.3 Wire and Operate Hermetic PSC Motors |
304 | Lab 88.4 Troubleshooting Hermetic Compressor Motors |
305 | Lab 88.5 Identifying Types of Starting Relays |
306 | Lab 88.6 Wire and Operate Hermetic Split Phase and Capacitor Start Compressors |
307 | Lab 88.7 Wire and Operate CSR Motors |
308 | Lab 88.8 Install Hard Start Kit |
Section 12 | |
309 | Lab 89.1 Wire Disconnect Switch and Power Supply |
310 | Lab 89.2 Wiring a Packaged Unit |
311 | Lab 89.3 Wiring a Split System |
312 | Lab 90.1 Belt Drive Blower Complete Service |
313 | Lab 90.2 Cleaning Coils |
314 | Lab 90.3 Types of Motor Bearings |
315 | Lab 90.4 Belt Drives |
316 | Lab 90.5 Direct Drive Motor Applications |
317 | Lab 92.1 Waterflow Effect on System Performance |
318 | Lab 92.2 Effect of Airflow on System Performance |
319 | Lab 92.3 Troubleshooting, Scenario 1 |
320 | Lab 92.3 Troubleshooting, Scenario 2 |
321 | Lab 92.3 Troubleshooting, Scenario 3 |